Most 214's can be
adjusted to run properly through years of normal
use without any difficulty but there are some
movements which can only be described as over-active. The adjustment of an
over-active movement is so tenuous that any external force will cause it to
speed up. This explains why some watches run great on the dresser but too fast
when worn while others will run well for a while until a hard bump
causes them to slip
out of adjustment.
The bottom of each tuning fork tine was notched at the factory to set the frequency (photo). A relative few have tuning forks that were cut to the lower end of their tolerances. This was OK when the magnets were energized by 1.3 volts but at 1.5 volts these forks are over-active. This causes them to index two teeth instead of one either periodically or with every stroke.
Unfortunately, there is no way to know in advance which movements have this problem. The problem is usually found while adjusting the movement but it is possible for a very few to slip by undetected.
Previously the only way to correct the problem was to replace the tuning fork with one that has thicker tines but the supply of good forks is rapidly decreasing. Fortunately though, I now have a better way to eliminate the problem. A diode which lowers battery voltage in the circuit by 0.2 volts can be installed in the coil. This is really the best possible solution. The watch will perform as it did when new and battery problems will never occur again. This inexpensive modification is not noticeable and it is reversible.
WATER ENTRY
Click on thumbnails for a
larger image and use your back button to return.
Bulova was overly optimistic in 1960 when they first marked the 214 model as "waterproof". Accutron 214's have always been susceptible to water damage. There are 4 places where water can enter.
The crystal
The setting stem (crown)
The battery hatch
The back cover
In my opinion, the seal around the plastic crystal
is the main source of water entry. One solid whack is enough to crack the
crystal and lose the seal. A new crystal can solve this problem but the setting
stem is another matter entirely.
The recessed setting stem on the back cover of a 214 is it's signature feature. The stem assembly has a built-in "O" ring which can't be replaced without risking damage to the stem itself. From 1960 through the late 80's In order to remain "waterproof", Accutrons received a new stem every five years or so. Since new replacement stems are no longer available the stem remains a weak link for water entry.
The photos above show a progression of five case backs.
The first is dated 1968 (M8) and is marked "WATERPROOF".
The second photo shows an early 1969 (M9) case back marked "WATERPROOF".
Sometime during 1969 the waterproof stamp was replaced with "WATER RESISTANT" as can be seen in the third photo.
By the end of 1969 all reference to water has been removed from the 69 case shown in the fourth photo.
As can be seen in the
last photo of a 1970 (N0) case back, the words "WATERPROOF" and "WATER
RESISTANT" are conspicuous by their absence.
Because of lagging
sales, "WATER RESISTANT" appears once again on most of the models made
after 1971.
NOTE: In 1969 as 214 sales lagged behind the newer, more popular 218 models, Bulova introduced a new series of Spaceview watches which sported wide gray chapter rings. They were very popular and sold well in 1969 and 1970. Most of these post 69 models have back covers that are not marked "WATERPROOF" or "WATER RESISTANT".
RUST AND CORROSION
Click on thumbnails for a larger image and
use your back button to return.
This kind of damage is commonly found in watches that have been exposed to moisture when they have no protective coating of oil on the jeweled bearings.
These before and after photos show the bearing shaft of a center pinion gear that has been ruined by corrosion.

Photo of the cap jewel with it's
rust plugged center hole.
Contrary to popular belief, the grade of stainless steel used for watch cases will rust over a period of years. Water gets in between the metal parts where it can stay wet for days and the inevitable result is shown in the photo of the Astronaut with its bezel removed at the left.
Corrosion inside of the rotating bezel ring will eventually weaken the hub which is pressed over the crystal. The hub is under tension and so it tends to crack at the weakest point.
The
rust on an old bezel ring tends to lock the ring onto the old crystal so it will
generally not fall off even when a crack develops. The problem comes when the
ring is disassembled, cleaned, and an attempt is made to press it onto a new
crystal. At this point the hub will break at the crack and becomes useless.
The moral of this story is plain. Now that we are in the 5th decade of Accutron history, please keep your fine old Accutron 214 away from water. After preserving it for such a long time, it would be a shame to lose it to corrosion now.
COIL
DAMAGE
Click on thumbnails for a larger image and
use your back button to return.
These
photos shows a problem that can occur when a battery is installed incorrectly
and then is forced against the plastic battery housing when the battery hatch is
screwed down.

IMPORTANT:
TO PREVENT DAMAGE TO THE COIL, MAKE
CERTAIN THAT THE BATTERY IS SEATED ALL THE WAY DOWN AND FLAT AGAINST THE CIRCUIT
BOARD. IF YOU FEEL PRESSURE BEFORE THE BATTERY CAP IS SCREWED ALL THE WAY DOWN,
REMOVE THE CAP AND RE-SEAT THE BATTERY
INDEX MECHANISM
Click on thumbnail for a larger image
and use your back button to return.

Tiny jewels are cemented to the tips of the Index and Pawl Fingers. If a jewel falls off, the sharp edge on the tip of the steel finger will spring down and contact the Index Wheel.
This photo shows both jewels on the Index Wheel.
In this photo, the tuning fork is missing its index jewel. Both fingers have been lifted away from the wheel for clarity in the photo. The steel finger that used to hold the index jewel had been grinding against the index wheel causing damage to the teeth. The index wheel is the heart of the mechanism. It is a ratchet wheel that is pushed by the vibrating tuning fork.
EARLY BATTERY CONTACT SPRING
The very first battery contact spring was a circular design with three contact fingers protruding inward toward the center and bent upward to contact the battery.
This design had a nasty habit of losing one after another of the contact fingers as they became work hardened due to bending. The fingers often became seriously bent when the battery was not placed correctly in the battery nest. Attempting to straighten one of these badly bent fingers usually results in the finger breaking off. Worst of all, the contact spring is permanently swaged onto the hatch and is not replaceable. Precisely because of this problem, that design was changed to one that incorporated a replaceable spring early in 1962.
Back in the day, damaged contact springs were repaired by installing new hatches. Today, stainless steel hatches with replaceable springs are available. The supply comes from still plentiful parts watches but with very few exceptions, solid gold 214 cases are not scavenged for parts.
HATCH SPRING CONVERSION:
Fortunately, conversion of solid gold hatches can be accomplished by machining the hatch to accept the standard contact spring design. (see photos below)

BEFORE AFTER
Click on thumbnail for a larger image and
use your back button to return.
INTERMITTENT BATTERY
CONTACT
If your 214 kept decent time right up until the battery was replaced but has
been losing time ever since, the problem is most likely poor battery contact.
This is a fairly common occurrence which can often be avoided (or corrected) by
doing the following:
1) Make certain that the plastic insulator is not hanging up on the battery nest, preventing the battery from having solid contact with the coil. After dropping a battery into your 214’s battery compartment, it may appear to be seated properly even when it is not. Always press the center (metal part) of the battery down firmly until it seats against the bottom contact. This is necessary because the plastic spacer is often too large to enter its opening thus preventing the bottom of the battery from seating all the way down.
2) Check to see that the contact spring installed on the under side of the battery hatch has not been flattened. Check to see that the spring moves down freely when pressed and that it pops back up when released. The spring must provide positive pressure against the top of the battery.
Left: Early
battery contact spring (1960/1961)
Right: Common battery contact spring (1962 on)
IMPORTANT:
TO PREVENT DAMAGE TO THE COIL, MAKE
CERTAIN THAT THE BATTERY IS SEATED FLAT AGAINST THE CIRCUIT BOARD. IF YOU FEEL
PRESSURE BEFORE THE BATTERY CAP IS SCREWED ALL THE WAY DOWN, REMOVE THE CAP AND
RE-SEAT THE BATTERY
JUMP-STARTING A NEW BATTERY
Most 214’s will start spontaneously when a new battery is
installed but some will not. Over the years the permanent magnets on the tips of
your tuning fork may have lost some of their strength. If this is the case you
will need to jump-start the movement. A sharp smack with the palm or knuckles of
your hand at the 3 or 9 o’clock position should cause the tuning fork to start
to vibrate. Once started the watch will perform normally until the battery dies.
DAMAGED LUGS
Click on thumbnails for a larger
image and use your back button to return.
This is what happens when a steel bracelet
grinds against gold or gold-filled lugs for a long period of time.
Particularly dangerous
are the spring loaded, telescoping ends found on many modern bracelets.

DISCOLORED DIALS

When the dial was manufactured, it was nickel
plated and then coated with either a clear or an amber colored coating. The
coating helps to protect the plating from oxidation. The spotted areas on old
dials could be the coating which has darkened with age but it can also be the
plating. As the coating ages, it becomes crazed, allowing air and moisture to
reach the plating below. Often, air and moisture can penetrate the plating to
the base metal and the nickel plating becomes peppered with tiny bumps which are
caused by corrosion blooms beneath the plating.
More To Come......
Home
Accutron
Repair/Restoration Custom
Dials The Workshop
214's
For Sale Bands
For Sale Parts &
Accessories
Accutron History
Spaceview
History
Photo
Gallery
Luminous Gallery
Vintage Ad Gallery
Clock
Gallery
Band
Gallery
F.A.Q.
Accutron
Problems
Batteries
Booklets
Message
Board
For
Sale By Owner
Feedback
Contact
Information
Lost/Stolen